authorDimitri Fedrau <[email protected]>2025-10-16 05:20:38 +0000
committerJonathan Cameron <[email protected]>2025-10-19 10:46:24 +0000
commit7b8dc11c0a830caa0d890c603d597161c6c26095 (patch)
treed9c303fd3dbb05c543453e5d2b24517ae3ee1854 /scripts/basic/docproc.c
parentiio: imu: st_lsm6dsx: fix array size for st_lsm6dsx_settings fields (diff)
downloadkernel-7b8dc11c0a830caa0d890c603d597161c6c26095.tar.gz
kernel-7b8dc11c0a830caa0d890c603d597161c6c26095.zip
iio: humditiy: hdc3020: fix units for temperature and humidity measurement
According to the ABI the units after application of scale and offset are milli degrees for temperature measurements and milli percent for relative humidity measurements. Currently the resulting units are degree celsius for temperature measurements and percent for relative humidity measurements. Change scale factor to fix this issue. Fixes: c9180b8e39be ("iio: humidity: Add driver for ti HDC302x humidity sensors") Reported-by: Chris Lesiak <[email protected]> Suggested-by: Chris Lesiak <[email protected]> Reviewed-by: Javier Carrasco <[email protected]> Signed-off-by: Dimitri Fedrau <[email protected]> Cc: <[email protected]> Signed-off-by: Jonathan Cameron <[email protected]>